Description
16
BCL 34
Leuze electronic
The input can be specified as a PT commentary or in the BCL Config parameter list, e.g.,
PT0001610x.
Using the maintenance display, new settings for the BCL can be tried quickly and easily,
without having to project these settings via the PROFIBUS. If these settings are to be
accepted for standard operation, these must be configured via PLC.
Notice!
With very few exceptions, the BCL 34 is configured via the PROFIBUS connection
group.Parameters which were set via the service interface are, therefore, overwritten in
PROFIBUS operation by the parameters stored in the project. If parameters in the project
were not explicitly changed, the corresponding default parameters are transferred.
In the BCLConfig configuration software, the parameter input fields which can be overwrit-
ten by the PROFIBUS are displayed with a blue background. Parameter input fields which
are not overwritten by the PROFIBUS are displayed with a white background.
If these parameters were changed, they are stored in one of the available parameter mem-
ories in the MS 34. They are, thus, safely stored even if a BCL 34 is replaced.