Commissioning steps at a glance
Leuze electronic
BCL 34
11
TNT
35/7-2
4
V
Connecting the PROFIBUS
The PROFIBUS is connected via
HOST/BUS IN
or, in the case of a continuing network, via
BUS OUT
. If
BUS OUT
is not used, the PROFIBUS must be terminated at this point with
an M12 terminator plug (see "Accessories" on page 29.).
Figure 3.4:
BCL 34 with MS 34 103/MS 34 105 - Connection HOST/BUS IN and BUS OUT
Configuration via the PROFIBUS hardware manager
PROFIBUS manager
Install the GSE file associated with the BCL 34 in the PROFIBUS manager of your control.
Activate the required modules, including at least one of the modules 20 … 27.
Figure 3.5:
Example PROFIBUS manager
Store the slave address for the BCL 34 in the PROFIBUS manager. Ensure that the address
is the same as the address configured in the device. As soon as the BCL 34 is addressed
and configured correctly and the PROFIBUS functions, the status LED at the MS 34 104 or
MS 34 105 lights up in green.
Socket connector
(A coded)
Socket connector
(A coded)
Socket connector
(B coded)
Plug connector
(B coded)
Plug connector
(A coded)
1
2
3
4
5
6
7
/SERV
VIN
TXD
RXD
SCL
SDA
GND
/INT
SWIN
SWOUT
3
2
1
4
GND
VIN
FE
1
2
3
4
VOUT
FE
SWIN
SWOUT
GND
GND 3
2
1
4
FE
A (N)
B (P)
VCC
VCC 1
2
3
4
A (N)
B (P)
GND
FE
SW IN/OUT
BUS OUT
HOST/BUS IN
PWR
SERVICE
Summary of Contents for BCL34
Page 1: ...BCL34 Barcode reader GB 05 10 08 50038851 T E C H N I C A L D E S C R I P T I O N...
Page 98: ...Appendix 96 BCL 34 Leuze electronic 12 Appendix 12 1 EU Declaration of Conformity...
Page 102: ...Index 100 BCL 34 Leuze electronic V Vibration 18 W Warm up time 18 Warning notices 8 Weight 17...