Commissioning steps at a glance
12
BCL 34
Leuze electronic
Connecting the switching input/switching output at the BCL 34
The switching input/switching output is connected via SW IN/OUT.
Figure 3.6:
BCL 34 with MS 34 103/MS 34 105 - Connection SW IN/OUT
Connecting the Modular Service Display MSD 1 101
The MSD 1 101 is connected via cable KB 034-2000 (M12 connection on SERVICE and
M12 connection on MSD 1 101, see "Connection cable KB 034 2000" on page 32. on ).
Figure 3.7:
BCL 34 with MS 34 103/MS 34 105 - Connection SERVICE
The BCL 34 can be accessed via the MSD 1 101 using the service interface.
Notice!
Changes which were made via the service interface on the BCL 34 are lost following initial-
isation on the PROFIBUS.
Socket connector
(A coded)
Socket connector
(A coded)
Socket connector
(B coded)
Plug connector
(B coded)
Plug connector
(A coded)
1
2
3
4
VOUT
FE
SWIN
SWOUT
GND
SWIN
SWOUT
3
2
1
4
GND
VIN
FE
GND 3
2
1
4
FE
A (N)
B (P)
VCC
VCC 1
2
3
4
A (N)
B (P)
GND
FE
1
2
3
4
5
6
7
/SERV
VIN
TXD
RXD
SCL
SDA
GND
/INT
SW IN/OUT
BUS OUT
HOST/BUS IN
PWR
SERVICE
Socket connector
(A coded)
Socket connector
(A coded)
Socket connector
(B coded)
Plug connector
(B coded)
Plug connector
(A coded)
1
2
3
4
5
6
7
/SERV
VIN
TXD
RXD
SCL
SDA
GND
/INT
SWIN
SWOUT
3
2
1
4
GND
VIN
FE
1
2
3
4
VOUT
FE
SWIN
SWOUT
GND
GND 3
2
1
4
FE
A (N)
B (P)
VCC
VCC 1
2
3
4
A (N)
B (P)
GND
FE
SW IN/OUT
BUS OUT
HOST/BUS IN
PWR
SERVICE
Summary of Contents for BCL34
Page 1: ...BCL34 Barcode reader GB 05 10 08 50038851 T E C H N I C A L D E S C R I P T I O N...
Page 98: ...Appendix 96 BCL 34 Leuze electronic 12 Appendix 12 1 EU Declaration of Conformity...
Page 102: ...Index 100 BCL 34 Leuze electronic V Vibration 18 W Warm up time 18 Warning notices 8 Weight 17...