PROFIBUS
Leuze electronic
BCL 34
83
TNT
35/7-2
4
V
8.3.33
Service
Module 47
The
service
function permits the parameter set of the BCL 34 to be reset to factory
settings, corresponding to the command "PC20" via the service interface.
However, parameters are only reset permanently if they have been altered via BCL-Config,
or if the device is connected to a hood with integrated connectors using the wrong param-
eter set.
After the reset function has been activated, the device carries out a reset and is freshly
configured on the PROFIBUS. Potentially incorrect parameter settings via PROFIBUS
continue to be active.
Parameters
none
Input Data
Output Data
Input Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Status byte
Shows the state of the reset to factory
settings
0
unsign8
0x00: Not active or successfully
concluded
0xFF: reset is currently being car-
ried out
0xF1: EEPROM access error
0x00
–
47b
Input data length: 1 byte
a
Output Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
PC20_Over_Profibus
Reset of parameters to
factory settings
0.0
Bit
0 -> 1: reset the parameters
1 -> 0: standard operation
0
–
47a
Output data length: 1 byte
b