DOOR CONTACT CONNECTION
The Protégé Reader Expander allows the connection of
up to 4 contacts for monitoring and controlling access
control doors. Each zone on the reader expander can be
used for the door function that is automatically assigned
and as a normal zone input on the system. The following
example shows the connection of a normally closed door
position monitoring contact to monitor the open, closed,
forced and alarm conditions of the door.
DOOR LOCK CONNECTION
The Protégé Reader expander provides a connection for 2
electric strike locks with full monitoring of the lock circuit
for tamper and over current/fuse blown conditions. The
door lock monitoring can be disabled if it is not required.
ZONE INPUT
The Protégé Mini Reader Expander can monitor the state of
up to 6 zone inputs such as magnetic contacts, motion
detectors and temperature sensors. The Controller
supports normally opened and normally closed
configurations with or without EOL resistors on a per zone
configuration setting, the diagram below shows how to wire
a zone with EOL resistors enabled.
SPECIFICATION
Power Supply
DC Input Voltage
12VDC
(10.5VDC Min, 14.0VDC Max)
Operating Current
80mA (Typical)
Communication
RS-485 Module
Network
Outputs
Lock Outputs
2 FORM C Relay Outputs
PGM Outputs
6 (50mA Max) Open Collector
Inputs
Zone
8 (500ms to 40sec Input Speed)
Tamper
1 (Normally Closed)
Trouble Zone
16
Dimensions
PCB Dimensions
92mm X 210mm
3.6"
X
8.3"
*Specifications are subject to change without notice, please
visit www.integratedcontroltechnology.com for the updated
information.
Unit C, 6 Ascension Place, Mairangi Bay, P.O. Box 302-340
North Harbour, Auckland, New Zealand.
Phone: +64 (9) 476 7124
y
Fax: +64 (9) 476 7128
www.integratedcontroltechnology.com
Mini 2 Reader Expander
Quick Start Guide
PRT-RDM2
INTRODUCTION
The Protégé Reader Expander extends the number of card
reader inputs on the system by 2, number of zone inputs
by 8 (4 zones used for door monitoring and control and
up to eight can be used for extended functionality) and
the number of PGM outputs by 8 (includes 2 monitored
lock control outputs).
•
4 Wiegand Reader Mode for 2 Entry/Exit Doors Per
Reader Expander
•
Secure Encrypted RS-485 Module Communications
•
8 Zone Inputs
•
2 Lock FORM C Relay PGM Outputs
•
6 Open Collector PGM Outputs (Reader Control
Outputs)
•
Smart Reader Missing/Tamper Monitoring
•
Online and Remote upgradeable firmware
For a full installation manual or more information on the
Protégé Reader Expander and other Integrated Control
Technology products please login to our website
www.integratedcontroltechnology.com