Specifications
28
BCL 34
Leuze electronic
Our recommendation:
• Use BCL 34 R1x100
• AutoRefl mode with or without reading gate control (single)
The maximum distances between the reflector and the BCL depend on the reflector used.
A summary is provided in the following table. The fundamental arrangement of reflector and
BCL is shown in figure 5.12.
*) Reflective tape no. 2 is included
Application example: automatic reflector activation
Figure 5.12:
Reflector arrangement for autoReflAct
Reflector type/reflective tape
Max. distance (mm)
Max. angle (°)
Order No.
reflective tape no. 2 *)
1200
15
500 11523
TK 100x100
2000
20
500 03192
TKS 50x50
1000
20
500 22814
Table 5.5:
Examples of reflectors which may be used
Reflector
Summary of Contents for BCL34