PROFIBUS
80
BCL 34
Leuze electronic
8.3.29
Code Direction
Module 43
The module defines input data for the communication of the detected code direction of the
currently transmitted barcode.
Parameters
none
Input Data
Output Data
none
8.3.30
Number Of Digits
Module 44
The module defines input data for the communication of the number of digits of the
currently transmitted barcode.
Parameters
none
Input Data
Output Data
none
Input Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Code Direction
Code direction of the transmitted barcode
0
unsign8
0: Normal
1: Inverse
0
–
Input data length: 1 byte
a
Input Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Number Of Digits
Number of digits of the transmitted barcode
0
unsign8 0 … 48
0
–
Input data length: 1 byte
a
Summary of Contents for BCL34