PROFIBUS
82
BCL 34
Leuze electronic
8.3.32
Alignment mode 1
Module 46
The module defines input and output data for the alignment mode of the BCL. The align-
ment function is used for easy positioning of the BCL.
Notice!
The alignment mode should not be used
in connection with module 15
(AutoReflAct) as
this may lead to erroneous functionality.
Parameters
none
Input Data
Output Data
Input Data
Description
Rel.
addr.
Data type
Value Range
Default
Unit
CR to
module
Scans per barcode
Number of scans between the first and last
detecting of the barcode
0
unsign16 0 … 65535
0
–
Scans with
information per
barcode
Number of scans between the first and last
detecting of the barcode, which have contributed
information for the formation of the result
2
unsign16 0 … 65535
0
–
46c
Input data length: 4 bytes consistently
a
b
Output Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Alignment
mode
Signal, activates the alignment
mode
0.0
Bit
0 -> 1: On
1 -> 0: Off
0
–
Output data length: 4 byte consistently
c