Symptom
Action
3. Check the disc or package for regional coding. You might need to
purchase a disc with coding for the region where you are using the
product.
4. Restart the disc player program.
5. Restart the server.
6. Run any optical drive diagnostic programs if you have.
7. Reinstall the optical drive and reconnect cables.
8. Replace the signal cable for the optical drive.
9. Replace the optical drive.
Storage drive problems
Symptom
Action
A newly installed non-hot-swap storage
drive is not recognized.
1. Ensure that:
• The drive is installed into the correct drive bay.
• The signal cable and connector are not damaged.
• The drive is securely connected to the correct SATA connector on
the system board and the SATA connector is enabled in the Setup
Utility program. See “Using the Setup Utility program” on page 25.
• All cables and jumpers (if any) are installed correctly.
2. Run any diagnostic programs (if you have) to test the drive.
3. Reinstall the drive and reconnect cables.
4. Replace the signal cable for the drive.
5. Replace the power cable for the drive.
6. Replace the drive.
Multiple storage drives fail.
1. Run any diagnostic programs (if you have) to test the drives.
2. Ensure that the cable connections are correct.
3. Reinstall the drives and reconnect cables.
4. Replace the affected cables.
5. Replace the failing drives.
6. (Trained service technician only) Replace the system board if you
suspect a problem with the system board.
Memory module problems
Symptom
Action
The amount of system memory that is
displayed is less than the total capacity
of the installed physical memory modules
and you suspect a memory module
problem.
1. Ensure that:
• All memory modules are the correct type supported by the server.
See “Memory module installation rules” on page 71.
• You followed the memory module installation rules. See “Memory
module installation rules” on page 71.
• All memory modules are seated correctly and securely.
• The system firmware is up-to-date.
2. Reinstall the memory modules.
3. Replace the suspect memory modules.
4. (Trained service technician only) Replace the system board.
.
Troubleshooting and diagnostics
105
Summary of Contents for ThinkServer TS150
Page 14: ...xii ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Page 52: ...38 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Page 116: ...102 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Page 124: ...110 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Page 136: ...122 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Page 146: ...132 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Page 147: ......
Page 148: ......