F
UNCTIONAL
D
ESCRIPTIONS
4.10 External data input/output
4-29
8310/8610-8
•
program processing signals (storage location 2/9)
•
range signals (storage location 3/61)
•
actual position (storage location 3/81)
•
nominal position (storage location 3/80)
•
correction value (storage location 3/82)
With an appropriate selection of the decades, you can output different types of
data at one single data output. This allows a more effective use.
Example: Four machine functions, program and sentence number (the latter
with two digits, at maximum: 99) and the program processing signals
of one unit shall simultaneously be available at the first data output
A
1
.
Programming:
storage
location
variant
meaning
2/2
2
»8 out1.2«
8 machine functions at decades 2 + 3
2/8
1
»output 1«
sentence and program number at decades
0...2, 4 + 5
2/9
3
»out 1.3«
program processing signals at decade 3
Output:
a) sentence and program number
at decades 0 + 1 and 4 + 5; the
3rd digit of the sentence number
at decade 2 must be zero
b) lower four machine functions
M1...M4 at decade 2; the upper
four machine functions M5...M8
at decade 2 must not be
programmed (=0)
c) program processing signals at
decade 3
13
12
11
10
9
8
7
6
5
4
3
2
1
25
24
23
22
21
20
19
18
17
16
15
14
program
number
stop
end of program
end of block
end of sentence
M4
M3
M2
M1
sentence
number
a b c
A
1
M8
M5
5
4
3
2
1
0
E180053A