3-6
3.1
Automatic mode
O
PERATING
M
ODES AND
S
TATES
8310/8610-8
°+.
Display the actual software version (this is possible in all
states of the automatic mode);
example:
a) with standard software
b) with special software
basic device GEL 8610 for 5 axes at max.
code for software options standard version
as before
number of special software
E
1
8
0
0
7
7
J
examples for software options (cf. appendix C):
Op x1
: transmission protocol LB2
Op x2
: transmission protocols LB2 + GEL 131
Op 1x
: circular interpolation
Op 2x
: synchro control
%+.
Q
Display of date/time (only with serial interface – module V –
with integrated real time clock);
abort with
`
; cf. section 4.12
&+;
>
Write data to memory card (option): storing of operating and
machine parameters (with security inquiry, refer also to storage
location 1/6 (GEL 8310) or 1/9 (GEL 8610), respectively)
°+;
<
Read data from memory card (option): loading of operating
and machine parameters (only possible if the Controller is in
the reset state for all units and the card has at least already
once been written, with security inquiry)
%+!
Y+Ö
Manual operation: slow speed forward (only possible in the
interrupted or reset state of the automatic mode and during
teach-in operation; cf. storage locations 3/18...24);
as this is an axis function, the axis to be controlled first has to
be displayed (see further above:
°+0
and
°+!/^
);
High level must to be applied at the /stop input for the
respective axis (P4/P7/P10)
&+!
Y+Ü
Manual operation: fast speed forward
(see explanations of slow speed forward)