6-10
6.1 Warning and error messages
T
ROUBLE SHOOTING
8310/8610-8
Warning or error
message
Cause, situation
Remedy, reaction
Referenc too high
reference measure is too high
Input monitoring:
value of the reference
measure exceeds the
specified »Pos. max« value
(storage location 3/72)
Enter a lower value or
specify »Pos. max« new
Referenc too low
reference measure is too
Input monitoring:
value of the reference
measure is lower than the
specified »Pos. min« value
(storage location 3/71)
Enter a higher value or
specify »Pos. min« new
Speed too high
A nominal speed value has
been entered that is larger
than the programmed
maximum value (storage
location 3/32) considering a
programmed multiplier and a
decimal point for the speed
rate input (storage locations
3/45 and 3/46)
Enter a lower value
write m.card ?
write memory card?
The
&+;
keys resp.
>
have been actuated in order
to safe the machine para-
meters and nominal values
on the memory card inserted
Confirm with
;
or abort
with any other key
Write protect
You tried to write on a
memory card although the
write protection has been
activated at the machine
parameter 1/6 (GEL 8610:
1/9)
Modify the machine para-
meter accordingly
If display B shows a point only, the supply voltage remains under the
minimum value stated in appendix C under ‘Operational data’. In this
case the Controller stops working, because it is in an undefined operat-
ing state, which has to be terminated as quickly as possible: Switch off
the equipment and perform the necessary measures, so that the supply
voltage will remain stable inside the limits.