A-42
S
TORAGE LOCATIONS FOR MACHINE PARAMETERS
8310/8610-8
3
77
Speed in
Ext. data input of a speed value
Specifies to which data input the speed rate specification is to be applied (in BCD
code, max. 6 digits), optionally with continuous sentence processing specifier ‘
g
’
(decade 10
5
, bit 2
3
=^ High); refer to sections 4.2, 4.3, and 4.10.1
0
program
no external data specification
1
input 1
data specification without continuous sentence processing
at the 1st data input E
1
(range of values: 0 ... 999,999)
2
i1
g
data specification with continuous sentence processing at
the 1st data input E
1
(range of values: 0 ... +799,999)
3
input 2
data specification without continuous sentence processing
at the 2nd data input E
2
4
i2
g
data specification with continuous sentence processing at
the 2nd data input E
2
5
input 3
data specification without continuous sentence processing
at the 3rd data input E
3
6
i3
g
data specification with continuous sentence processing at
the 3rd data input E
3
GEL 8610 only:
7
input 4
data specification without continuous sentence processing
at the 4th data input E
4
8
i4
g
data specification with continuous sentence processing at
the 4th data input E
4
3
78
79
Reserve
not used for the standard version
--------