S
TORAGE LOCATIONS FOR MACHINE PARAMETERS
A-23
8310/8610-8
3
14
R.switch
Reversing switch signal
Specifies the switching level of the
reversing switch
signal for the automatic
reference search routine; refer to section 4.6
0
low
Low level =^ logical 1
1
high
High level =^ logical 1
3
15
Ref.val.
Value of the 1st reference measure
Under the precondition that the
reference2/1
signal is not active (Low level at P22),
the actual value is set to this value as soon as the drive exceeds the reference
point; the here specified value can also be changed via direct entry in the
Automatic mode under the above stated conditions (refer to storage location 3/9
and section 4.6, 2nd reference measure: 3/85)
XXXXXXXX
max. 8 digits incl. sign (-) and decimal point; specification of
the value in actual measuring units
3
16
Cal. spd.
Auto calibration speed rate
Speed rate of the automatic reference search routine up to the reversal point
(proximity switch); refer to section 4.6
XXXXXX
max. 6 digits incl. decimal point; value in actual measuring
units per second
3
17
Rev.spd.
Reversing speed rate
Speed rate of the automatic reference search routine from the reversal point
(proximity switch) towards the reference point; refer to section 4.6
XXXXXX
max. 6 digits incl. decimal point; value in actual measuring
units per second