S
TORAGE LOCATIONS FOR MACHINE PARAMETERS
A-19
8310/8610-8
3. Axis parameters (3rd level)
3
1
Encoder
Actual value adjustment
Specification of the used encoder and setting of the edge evaluation of the 0° and
90° tracks at the count input and the coding of the connected encoder (refer also to
section 5.2)
0
incr. x1
incremental encoder with 1-fold edge evaluation (nominal
pulse number)
1
incr. x2
incremental encoder with 2-fold edge evaluation (double
nominal pulse number)
2
incr. x4
incremental encoder with 4-fold edge evaluation (quadruple
nominal pulse number)
3
Gray
absolute encoder, Gray code
4
/Gray
parallel absolute encoder, Gray code with logic reversal
5
binary
parallel absolute encoder, binary code
6
/binary
parallel absolute encoder, binary code with logic reversal
7
BCD
parallel absolute encoder, BCD
8
/BCD
parallel absolute encoder, BCD with logic reversal
9
SSI 25b
25 bits multi-turn absolute encoder with serial data output
Gray code, refer to storage location 3/54
10
SSI 13b
13 bits single-turn absolute encoder with serial data output,
Gray code, refer to storage location 3/54
3
2
Directio
Count direction
Inverting of actual value counting direction
WARNING
It is mandatory to read sections 5.4 and 4.1.3 before performing any
changes!
0
no rever
no reversal of the count direction
1
reversal
reversal of the count direction
Summary of Contents for GEL 8310