24/29
Technical data sheet: S000074637EN-5
Updated: 12/03/2015
Created: 15/04/2014
Technical data sheet
Catalogue number(s): 0 484 22
KNX multiapplication controller 16 outputs
KNX multiapp
8. COmmUNiCa
8. COmmUNiCaTiON OBJECTS (CONTiNUED)
No.
Object name
function
Size
flags
215
(221, 227)
Program Fn
Program Fn
Output 1 1bit
1.002 DPT_
Bool
CT
Program Fn
Output 1
2bits
2.002 DPT_
Bool_Control
Program Fn
Output 1
4bits
3.007 DPT_
Control_Dim-
ming
Program Fn
Output 1
1bytes
5.010 DPT_
Value_1_
Ucount
Program Fn
Output 1
2bytes
7.001 DPT_
Value_2_
Ucount
Program Fn
Output 1
4bytes
12.001 DPT_
Value_4_
Ucount
The Program function Output 1 value is sent via the address linked with
this object when the program is triggered.
216
(222, 228)
Program Fn
Program Fn
Output 21bit
1.002 DPT_
Bool
CT
Program Fn
Output 2
2bits
2.002 DPT_
Bool_Control
Program Fn
Output 2
4bits
3.007 DPT_
Control_Dim-
ming
Program Fn
Output 2
1bytes
5.010 DPT_
Value_1_
Ucount
Program Fn
Output 2
2bytes
7.001 DPT_
Value_2_
Ucount
Program Fn
Output 2
4bytes
12.001 DPT_
Value_4_
Ucount
The Program function Output 2 value is sent via the address linked with
this object when the program is triggered.
217
(223, 229)
Program Fn
Program Fn
Output 3 1bit
1.002 DPT_
Bool
CT
Program Fn
Output 3
2bits
2.002 DPT_
Bool_Control
Program Fn
Output 3
4bits
3.007 DPT_
Control_Dim-
ming
Program Fn
Output 3
1bytes
5.010 DPT_
Value_1_
Ucount
Program Fn
Output 3
2bytes
7.001 DPT_
Value_2_
Ucount
Program Fn
Output 3
4bytes
12.001 DPT_
Value_4_
Ucount
The Program function Output 3 value is sent via the address linked with
this object when the program is triggered.
No.
Object name
function
Size
flags
218
(224, 230)
Program Fn
Program Fn
Output 4 1bit
1.002 DPT_
Bool
CT
Program Fn
Output 4
2bits
2.002 DPT_
Bool_Control
Program Fn
Output 4
4bits
3.007 DPT_
Control_Dim-
ming
Program Fn
Output 4
1bytes
5.010 DPT_
Value_1_
Ucount
Program Fn
Output 4
2bytes
7.001 DPT_
Value_2_
Ucount
Program Fn
Output 4
4bytes
12.001 DPT_
Value_4_
Ucount
The Program function Output 4 value is sent via the address linked with
this object when the program is triggered.
219
(225, 231)
Program Fn
Program Fn
Output 5 1bit
1.002 DPT_
Bool
CT
Program Fn
Output 5
2bits
2.002 DPT_
Bool_Control
Program Fn
Output 5
4bits
3.007 DPT_
Control_Dim-
ming
Program Fn
Output 5
1bytes
5.010 DPT_
Value_1_
Ucount
Program Fn
Output 5
2bytes
7.001 DPT_
Value_2_
Ucount
Program Fn
Output 5
4bytes
12.001 DPT_
Value_4_
Ucount
The Program function Output 5 value is sent via the address linked with
this object when the program is triggered.
Parameters
Setting
Active Program X
Yes /
No
This is a parameter that indicates if Program X should be used or not. If
not, no communication object parameters will be visible.
Program X name string
This is a parameter to name the program. There is no influence on the
program behavior.
Name Px_input
string
This is a parameter to name the input function.
input Size
1 bit
2 bits
4 bits
1 Byte
2 Bytes
4 Bytes
Here it is possible to make an adjustment to set the datapoint size of
the “Program Fn Input XXX” communication object.
Parameters
S
value Type
"
1
2
4
1
2
4
Here it is possible to
the comparison value
value
1
1
1 bit Enable/Disable
1
2
2
4
4
1
v
1
1
2
v
2
v
4
v
4
v
Here it is possible to
be compared to Prog
program sequence s
Name Px_
Out
-
put 1 (2
5)
str
This is a parameter
Output 1
(2
5) Size
1
2
4
1
2
4
Here it is possible to
the “Program Fn Out
S000074637EN-5.indd 24
20/05/15 10:16