KNX multiapplication controller 16 outputs
8. COmmUNiCaTiON OBJECTS (CONTiNUED)
e
flags
010 DPT_
tart
CRW
010 DPT_
tart
CRW
010 DPT_
tart
CRW
010 DPT_
tart
CRW
flags
10
DPT_
tiveEnergy
CR
epresents the measu-
010 DPT_
t
CW
.56 DPT_
alue_Power
CR
the measured
urrent value is
changes.
unication objects
8.5 Scenes
No.
Object name
function
Size
flags
1
Input Scene
Recall scene 17.001
DPT_Scene-
Number
CW
Scenes telegrams are received via the group address linked with this
object.
The scene value affects all ouputs using this scene number.
Each output channel can be assigned to 5 different instances.
Each output channel can be assigned to 5 differents scenario instances.
For Outputs A1, A2, B1, B2, those parameters are only available when
outputs are configured as switch "use separatly".
Parameters
Setting
Xn, Scenario Number
0
64
0 : No scenario
Xn, Scenario Order
Off
On
Off + Disable
On + Disable
Off
On
Enable
Disable
Here it is possible to make an adjustment to define the order action
that should be executed on the output when the corresponding scene
number is received.
Xn, Delay
immediate
, 500 ms,
1 second, 2 seconds,
5 seconds,10 seconds,
30 seconds, 1 minute,
90 sec., 2 min., 10 min.,
15 min., 30 min., 45 min.,
1 h, 90 min.
Here it is possible to make an adjustment to define a delay before
executing the order action on the output when the corresponding scene
number is received.
For Outputs A and B, those parameters are only available when they are
configured as "Roller shutter" or "Venitian blinds".
Parameters
Setting
Xn+(n+1), Scenario Number
0
64
0 : No scenario
Xn+(n+1), Scenario Order
Up
Down
Up + Disable
On + Disable
Up
Down
Enable
Disable
Here it is possible to make an adjustment to define the order action
that should be executed on the output when the corresponding scene
number is received.
Xn+(n+1), Delay
immediate
, 500 ms,
1 second, 2 seconds,
5 seconds, 10 seconds,
30 seconds, 1 minute, 90
s., 2 min., 10 min., 15 min.,
30 min., 45 min., 1 h, 90 min.
Here it is possible to make an adjustment to define a delay before
executing exclusive function the order action on the output when the
corresponding scene number is received.
For Outputs A and B, those parameters are only available when they are
configured as "Exclusive function".
Parameters
Setting
Xn+(n+1), Scenario Number
0
64
0 : No scenario
Xn+(n+1), Scenario Order
Do Not disturb
Make Up Room
Stop
Here it is possible to make an adjustment to define the order action
that should be executed on the output when the corresponding scene
number is received.
Xn+(n+1), Delay
immediate
, 500 ms,
1 second, 2 seconds,
5 seconds, 10 seconds,
30 seconds, 1 minute, 90 s.,
2 min., 10 min., 15 min.,
30 min., 45 min., 1 h, 90 min.
Here it is possible to make an adjustment to define a delay before
executing the order action on the output when the corresponding
scene number is received.
8.6 Program functions
3 program functions are available.
Each program function allows to generate up to 5 different commands
(fully configurable) triggered by one input condition (fully configurable).
No.
Object name
function
Size
flags
214
(220, 226)
Program Fn
Program Fn
Input 1bit
1.002 DPT_
Bool
CRW
Program Fn
Input 2bits
2.002 DPT_
Bool_Control
Program Fn
Input 4bits
3.007 DPT_
Control_Dim-
ming
Program Fn
Input 1bytes
5.010 DPT_
Value_1_
Ucount
Program Fn
Input 2bytes
7.001 DPT_
Value_2_
Ucount
Program Fn
Input 4bytes
12.001 DPT_
Value_4_
Ucount
This object is used to trigger the program function.
Depending on the “Input Size” parameter, this communication can have
different datapoint types.
S000074637EN-5.indd 23
20/05/15 10:16