User Manual of EL6-CAN AC Servo
www.leadshine.com
115
code
Content:
Motor speed out of control
Cause
Confirmation
Solution
UVW connection
error
UVW connection error
Encoder error
Encoder error
Replace motor
Special function
Set Pr1.37=4
Error
code
Main
Extra
Display:
“
”
Content:
Wrong pulse input frequency
Cause
Confirmation
Solution
Wrong pulse
input frequency
Error
code
Main
Extra
Display:
“
”
Content:
Electronic gear ratio error
Cause
Confirmation
Solution
Pulse input
frequency is too
high
Pulse input frequency is too high
Make sure the pulse frequency is
blew 500K
Error
code
Main
Extra
Display:
“
”
Content:
I/F input interface allocation error
Cause
Confirmation
Solution
The input signal are assigned
with two or more functions.
Check the value of Pr_400,
Pr_401, Pr_402,Pr_403,Pr_404 if
it is proper or not
Assure the value of Pr_400, Pr_401,
Pr_402, Pr_403, Pr_404 set correctly
The input signal aren’t
assigned with any functions.
Check the value of Pr_400,
Pr_401,Pr_402,Pr_403,Pr_404 if
it is proper or not
Assure parameter Pr_400, Pr_401,
Pr_402,Pr_403,Pr_404 set correctly
Error
code
Main
Extra
Display:
“
”
Content:
I/F input interface function set error
Cause
Confirmation
Solution
Signal allocation error
Check the value of Pr_400, Pr_401,
Pr_402,Pr_403,Pr_404 if it is proper or
not
Assure the value of Pr_400, Pr_401,
Pr_402, Pr_403, Pr_404 set correctly
Error
code
Main
Extra
Display:
“
”
Content:
I/F input interface function set error
Cause
Confirmation
Solution
The input signal are assigned
with two or more functions.
Check the value of Pr_410,
Pr_411, Pr_412, Pr_413, if it is
proper or not
Assure the value of Pr_410, Pr_411,
Pr_412,Pr_413 set correctly