User Manual of EL6-CAN AC Servo
www.leadshine.com
26
0A
Inertia ratio
%
-
-
-
-
0B
Actual positive
torque limit value
0.1%
-
-
-
-
0C
Actual negative
torque limit value
0.1%
-
-
-
-
0D
U phase current
detect value
0.1%
-
-
-
-
0E
W phase current
detect value
0.1%
-
-
-
-
5502
01
SI input signal
-
-
-
-
-
02
DO output signal
-
-
-
-
-
03
Reserved
-
-
-
-
-
04
Reserved
-
-
-
-
-
05
Bus voltage
V
-
-
-
-
06
Temperature
℃
-
-
-
-
07
Power on time
S
-
-
-
-
4.1.3 Device Profile Parameters (Group 6000h)
Index
Sub-
index
Name
Unit
Default
Min
Max
Mode
603F
0
Error code
-
-
-
-
ALL
6040
0
Control word
-
-
-
-
ALL
6041
0
Status word
-
-
-
-
ALL
605A
0
Quick stop option code
-
6
0
7
ALL
605B
0
Shut down code
-
0
0
1
ALL
605C
0
Disable operation code
-
0
0
1
ALL
605D
0
Halt option code
-
1
1
4
ALL
605E
0
Alarm stop code
-
0
0
2
ALL
6060
0
Mode of operation
-
8
1
11
ALL
6061
0
Mode of operation display
-
-
-
-
ALL
6062
0
Position demand value
Command
unit
-
-
-
pp/hm
6063
0
Actual internal position value
Encoder
unit
-
-
-
ALL
6064
0
Actual feedback position value
Command
unit
-
-
-
ALL
6065
0
Following error window
Command
unit
10000
0
2147483
647
pp
6066
0
Following error detection time
ms
10
0
65535
pp
606B
0
Internal command speed
Command
unit
-
-
-
pv
606C
0
Actual feedback speed value
Command
unit
-
-
-
ALL
6071
0
Target torque
0.1%
0
-32768
32767
pt
6072
0
Max torque
0.1%
3000
0
65535
ALL
6073
0
Max current
0.1%
-
-
-
ALL