User Manual of EL6-CAN AC Servo
www.leadshine.com
65
6.2 Panel Display and Operation
6.2.1 Panel Operation Flow Figure
Power on
Display one second
“
000000'
Panel initial
display content
Data monitor mode
ENT
M
ENT
ENT
ENT
ENT
Parameter set mode
Display
parameter value
Modify
parameter value
Write
Ready write
EEPROM write
mode
M
M
M
doouEP
PA_000
AF_Jog
d01SPd
PA_001
AF_ini
d35 SF
PA_639
AF_oF3
Display
parameter value
Display
parameter value
Modify
parameter value
Auxiliary function mode
Figure 6-1 the flow diagram of panel operation
(1)
The front panel display
rEAdY
for about one second firstly after turning on the power of the drive. Then if
no abnormal alarm occurs, monitor mode is displayed with the value of initial parameter ; otherwise, abnormal
alarm code is displayed.
(2) Press M key to switch the data monitor mode → parameter setting mode → auxiliary function mode →
EEPROM written mode.
(3)
If new abnormal alarm occurs, the abnormal alarm will be displayed immediately in abnormal mode no
matter what the current mode is, press M key to switch to the other mode.
(4) In data monitor mode, press
or
to select the type of monitor parameter; Press ENT to enter the
parameter type , then press
to display the high 4 bits “H” or low 4 bits “L” of some parameter values.
(5) In parameter setting mode, press
to select current editing bit of parameter No, press
or
to change
current editing bit of parameters No. Press ENT key to enter the parameter setting mode of corresponding
parameters No. Press
to select current bit of parameter value when editing it, press
or
to change the value
of the bit. Press ENT to save it and switch to the interface of parameter No.