User Manual of EL6-CAN AC Servo
www.leadshine.com
37
is valid, It will be valid
all the time
3rd notch filter will be updated all the time based on
adaptive performance.
3-4
Not use
Non-professional forbidden to use
Pr2.01
Name
1st notch frequency
Mode
F
Range
50~2000
Unit
Hz
Default
2000
Index
2201h
Set the center frequency of the 1st
notch filter
Notice
: the notch filter function will be invalidated by setting up this parameter to “2000”.
Pr2.02
Name
1st notch width selection
Mode
F
Range
0~20
Unit
-
Default
2
Index
2202h
Set the width of notch at the center frequency of the 1st notch filter.
Notice:
Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
Pr2.03
Name
1st notch depth selection
Mode
F
Range
0~99
Unit
-
Default
0
Index
2203h
Set the depth of notch at the center frequency of the 1st notch filter.
Notice:
Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
Pr2.04
Name
2nd notch frequency
Mode
F
Range
50~2000
Unit
Hz
Default
2000
Index
2204h
Set the center frequency of the 2nd
notch filter
Notice
: the notch filter function will be invalidated by setting up this parameter to “2000”.
Pr2.05
Name
2nd notch width selection
Mode
F
Range
0~20
Unit
-
Default
2
Index
2205h
Set the width of notch at the center frequency of the 2nd notch filter.
Notice:
Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
Pr2.06
Name
2nd notch depth selection
Mode
F
Range
0~99
Unit
-
Default
0
Index
2206h
Set the depth of notch at the center frequency of the 2nd notch filter.
Notice:
Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
Pr2.07
Name
3rd notch frequency
Mode
F
Range
50~2000
Unit
Hz
Default
2000
Index
2207h
Set the center frequency of the 3rd
notch filter
Notice
: the notch filter function will be invalidated by setting up this parameter to “2000”.
Setup invalid after opening self-adaptation function.