User Manual of EL6-CAN AC Servo
www.leadshine.com
84
The meaning of each bit is described below, depending on its value:
Homing
error
Homing
attained
Target
reached
Description
0
0
0
Homing procedure is in progress
0
0
1
Homing procedure is interrupted or not started
0
1
0
Homing is attained but target is not reached
0
1
1
Homing mode carried out successfully
1
0
0
Homing error occurred;
Homing mode carried out not successfully;
Velocity is not zero
1
0
1
Homing error occurred;
Homing mode carried out not successfully;
Velocity is zero
1
1
x
Reserved
6.8.3 Related objects
Object Dictionary
Description
Setup value
Units
6060H
Mode of operation
-
6040H
Controlword
6041H
Statusword
6098H
Homing method
6099H
Homing speeds
Command unit /s
609AH
Homing acceleration
Command unit /s
2
607CH
Home offset
Command unit
6.8.4 Example of homing mode
No
Command
Function
1
81 00 00 00 00 00 00 00
Reset all nodes. If you need to reset the specified node, the node
number is changed by modifying the two digits after 81 (note that it
is hexadecimal)
2
01 00 00 00 00 00 00 00
Start remote control for all nodes. If remote control of the specified
node needs to be started, the node number is changed by modifying
the two-digit number after 01 (note that it is hexadecimal).
3
2b
40 60
00 06 00 00 00
Write control word as 06
H
,
state machine switching status
Switch On Disabled->Ready to Switch On
4
2b
40 60
00 07 00 00 00
Read control word as 07H
,
state machine switching status
Ready to Switch On-> Switched On
The relay in the actuator is engaged at this point
5
2b
40 60
00 0f 00 00 00
Write control word as 0fH
,
state machine switching status
Switched On->Operation Enable. Servo-Enabled