User Manual of EL6-CAN AC Servo
www.leadshine.com
27
6074
0
Internal torque command
0.1%
-
-
-
ALL
6075
0
Rated current
mA
-
-
-
ALL
6076
0
Rated torque
mN.M
6077
0
Actual torque
0.1%
-
-
-
ALL
6079
0
Bus voltage
mV
-
-
-
ALL
607A
0
Target position
Command
unit
0
-214748
3648
2147483
647
pp
607C
0
Homing position offset
Command
unit
0
-214748
3648
2147483
647
ALL
607D
1
Minimum soft limit
Command
unit
0
-214748
3648
2147483
647
pp
2
Maximum soft limit
Command
unit
0
-214748
3648
2147483
647
pp
607E
0
Motor rotation direction
-
0
0
255
ALL
607F
0
Maximum protocol speed (Restricted
by 6080)
Command
unit /s
6080
0
Maximum motor speed
r/min
5000
0
6000
ALL
6081
0
protocol speed (Restricted by 607F)
Command
unit /s
10000
0
2147483
647
pp
6083
0
Profile acceleration
Command
unit /s/s
10000
1
2147483
647
pp/pv/
6084
0
Profile deceleration
Command
unit /s/s
10000
1
2147483
647
pp/pv
6085
0
Quick stop deceleration
Command
unit /s/s
100000
00
1
2147483
647
pp/pv/
hm
6087
0
Torque change rate
0.1%/s
100
1
2147483
647
pt
608F
1
Encoder resolution
Encoder
unit
-
-
-
ALL
2
Motor turns
-
6091
1
Electron gear molecule
-
1
1
2147483
647
ALL
2
Electronic gear denominator
-
1
1
2147483
647
ALL
6092
1
Number of pulses per rotation
Command
unit
10000
1
2147483
647
ALL
2
Number of physical axis turns
-
6098
0
Homing method
-
19
-6
37
hm
6099
1
High speed of homing
Command
unit /s
10000
0
2147483
647
hm
2
Low speed of homing
Command
unit /s
5000
0
2147483
647
hm
609A
0
Homing acceleration
Command
unit /s
2
10000
0
2147483
647
hm
60B0
0
Position feedforward
Command
unit
0
-214748
3648
2147483
647
60B1
0
Velocity feedforward(Restricted by
6080)
Command
unit /s
0
-214748
3648
2147483
647
pp/pv/
hm
60B2
0
Torque feedforward
0.1%
0
-32768
32767
ALL
60B8
0
Touch probe control word
-
0
0
65535
ALL
60B9
0
Touch probe statue word
-
-
-
-
ALL
60BA
0
Touch probe 1 rising
edge capture position
Command
unit
-
-
-
ALL