User Manual of EL6-CAN AC Servo
www.leadshine.com
93
Method 14
:
If the homing switch and positive limit switch is invalid, the motor will move in negative direction at low
speed. The motor stops after the homing switch invalid and the first encoder Z signal is valid, as shown in
figure.
If the negative limit switch is invalid and motor stops at the homing switch position when it starts to move,
the motor will move in negative direction at low speed. The motor stops after the homing switch invalid and
the first encoder Z signal is valid, as shown in figure.
If the homing switch and positive limit switch is invalid, the motor will move in negative direction at low
speed until the negative limit switch valid. Then the motor reverse the direction at high speed until the homing
switch valid. Then the motor move in negative direction at low speed. The motor stops after the homing switch
invalid and the first encoder Z signal is valid, as shown in figure.
If the positive limit switch signal is valid during the homing process, the status word (6041h) bit 13 will
be valid, indicating that the homing error and the motor will stop immediately.
Z signal
HOME-SWITCH
B
Start Position
Stop Position
High speed
6099h-01h
Low speed
6099h-02h
NOT signal
A
C
Method 17
:
This method is similar to method 1
NOT signal
A
B
Start Position
Stop Position
High speed
6099h-01h
Low speed
6099h-02h