![Laser Technology TruPoint 200h User Manual Download Page 51](http://html.mh-extra.com/html/laser-technology/trupoint-200h/trupoint-200h_user-manual_677865051.webp)
LTI TruPoint 200h User’s Manual • Section 5 - Function Menu
Page 49
Copyright (c)[2020] Laser Technology, Inc. All Rights Reserved. Unauthorized duplication, in whole or in part is strictly prohibited.
Volume Routine
Determine the volume of a room with 3 shots.
NOTE: The Volume calculations can use either the Slope Distance
or Horizontal Distance
in the routine. In Slope Distance
, three measurements (length, width, and height) will be slope
measurements. In Horizontal Distance
, the length and width will be horizontal measurements
and the height will use vertical measurements
of each shot for the length and width. Once in
the Volume routine, press the
and
buttons before taking first measurement to navigate
between the two. You can also navigate between the two different volume calculation results
Main Display Routine
1.
Short press the
button and use the navigation buttons to highlight
the Volume icon
.
2.
Press the
button to enter the Volume measurement routine.
3.
Select your first target and press the button, the laser pointer is active and laser indicator will
be display the pointer is on. Aim the laser pointer to the target. Shot 1 is displayed in lower
message area prompting you to measure the Distance to the “face” of the target
4.
Press-and-hold the
button, the laser will remain active for a maximum of 10 seconds
while acquiring data about the target. The measured slope distance appears in the main display
once the target is acquired. Shot 2 is then displayed in the lower message area.
5.
Take the second measurement/shot. Aim the laser pointer to the other portion of the room/target.
6.
Press-and-hold the
button, the laser will remain active for a maximum of 10 seconds
while acquiring data about the target. The measured slope distance appears in the main display
once the target is acquired. Shot 3 is then displayed in the lower message area.
7.
Take the third measurement/shot. Aim the laser pointer to the other portion of the room/target.
8.
Press-and-hold the
button, the laser will remain active for a maximum of 10 seconds
while acquiring data about the target. The measured slope distance appears in the main display
once the target is acquired. The Volume icon
and the calculated Volume result is
displayed.
**Draft B**