![Laser Technology TruPoint 200h User Manual Download Page 29](http://html.mh-extra.com/html/laser-technology/trupoint-200h/trupoint-200h_user-manual_677865029.webp)
LTI TruPoint 200h User’s Manual • Section 4 - Settings Menu
Page 27
Copyright (c)[2020] Laser Technology, Inc. All Rights Reserved. Unauthorized duplication, in whole or in part is strictly prohibited.
Vibrate
This feature provides short vibrating pulses/bursts to give a tactile confirmation and to reinforce that
the laser has locked on the target. A measurement will be displayed at the same time the Vibrate
feature is activated.
1.
Long press the
button and use the
and
buttons to highlight the Vibrate icon,
VIBRATE will be displayed in the lower message area.
2.
Press the
button to toggle the Vibrate setting on/off:
•
ON
: Turns the Vibrate feature on.
•
OFF
: Turns the Vibrate feature off.
3.
Press the Left Soft Key
to return to the main measurement screen.
This does not select an option and exits without saving the Vibrate setting option.
The unit will return to the last saved option.
4.
Press the Right Soft Key
to accept the Vibrate setting option and will exit to
the main measurement screen.
5.
When a target is acquired the unit will vibrate:
•
One time
: Low quality target, measurement resolution is 0.0 (tenths).
Range accuracy: ± 15cm (6 in)
•
Two times
: High Quality target for pulse technology,
measurement resolution is 0.00 (hundredths).
Range accuracy: ± 2-4 cm (0.8 -1.5 in)
•
Three times
: High quality target for phase technology,
measurement resolution is 0.000 (thousandths).
Range accuracy: ± 1.5 mm (0.05 in)
**Draft B**