5. Insert the motor brush back Inside the brush holder.
6. After the motor brush is re-seated and secured down, snap the cover back in place and repeat these instruc
-
tions for the other side.
7.15. Elevation Motor
When performing these remove/replace procedures, refer to Elevation Motor Parts (upright removed to improve
clarity), below. The parts are identified by the number shown in the figure.
1. Unplug the treadmill from its outlet.
2. Remove the motor cover.
3. Remove all weight from the elevation assembly by placing a suitably strong object under the motor pan, such as
a piece of 4x4 lumber, so that the wheels are off the floor.
4. Disconnect Elevation Motor wires.
5. Disconnect the Elevation Motor nut from the elevation assembly. To do this, loosen the two ¼-20 screws and
slide the two ¼” diameter pins out.