![background image](http://html2.mh-extra.com/html/landice/l7-club/l7-club_service-manual_3548044070.webp)
Repair Procedures
Safety Switch Assembly Switch Replacement
70
Figure 7-5.
Emergency Switch Assembly Switches
5. Reconnect the switch, noting which contacts must be connected to the harness as shown in the figure above
and “Interconnect Wiring Diagram - LTD and Home Models, ESI PWM Control PCB” on page
nect Wiring Diagram - Club Model” on page
21 as applicable.
6. Install the switch.
7. Install the Emergency Switch Assembly as outlined in “Lower Control Panel Electronics” on page
Lanyard Switch
Connect to these
two contacts (no
connection to the
middle contact)
Switch for
Emergency Stop
Connect to these
two contacts
Lanyard cord
through-hole
Cover