109
TÜV - Acceptance - Functions
4.0 Execution of the Watchdog Timing
In the submenu
C40 run time
test of the processor system DAVID-613 is possible it to limit all running
times for the next trip on 1,0 seconds.
1
The car is in a stop concisely place
2
Adjust the menu C-Diagnosis/ Inspection-session, C40 run time test in the processor DAVID-613.
All running times are set on one second
3
Call input by lowest/ highest call at the top side of the DAVID-613 central processing unit in the
menu C-Diagnosis /C- Call input
4
The plant opposes with run time error when going away from the stop
5
Unblocking the plant by In-/ Off switching the switch S33 or releasing of the reset in the menu C-
Diagnosis / C0-Reset
6
The system is again in normal operation
4.1 Carrying out the buffer trip
In the submenu C41 Buffer drive car of the processor system DAVID-613 it is possible to drive with the
return control downwards with the nominal speed without delay to the car buffer.
1 Switch on the S61 return control
2 In the DAVID-613 processor system, set the menu C-Diagnosis/ TÜV Acceptance, C41 Buffer Run Car.
3 Move the car with the return control in downward direction onto the buffer.
4 After the test has been completed, move the car up out of the buffer using the return control.
5 Switch off the return control S61. The control returns to normal operation
4.2 Carrying out the buffer run Counterweight
In the submenu C42 Counterweight buffer run of the DAVID-613 processor system, it is possible to run
with the return control downwards at the nominal speed without delay to the counterweight buffer.
1
Switch on the S61 return control
2
In the DAVID-613 processor system, set the menu C-Diagnose/ TÜV-Abnahme, C42-Puffergahrt Counter-
weight.
3
Move the car with the return control in upward direction until the counterweight rests on the buffer.
4
After the test has been completed, drive the car down out of the buffer using the return control.
5
Switch off the return control S61. The control returns to normal operation.