46
Connection of the door release contacts S9.1 of the lowest
shaft door
The terminals for connecting the door release contacts can be found on
ERG-2018 (cir-
cuit diagram sheet 6 of 8 / column 1-2).
The terminals are
9.1 and 9.1.
47
The terminals for connecting the door release contacts can be found on ERG-2018 (cir-
cuit diagram sheet 6 of 8 / column 1-2).
The
red
button is used to reset when locked in the pit!
48
Connection of Si-Kr. Folding support cabin S3M / S4M RSP
The terminals for connecting the maintenance folding jack switch in the case of a short-
ened pit are on the X6 /, (wiring diagram sheet 4 of 8 / column 5-6).
Terminals:
3L and 3M (normally open), as well as 4L and 4M (normally closed).
If not available, please bridge the terminals!
49
Attention! The normally open contact may only be connected when the power is off!
The terminals are
5L and 5M.
50
Installation of the H21 protective area traffic at RSP
51
Connection of the protective area traffic pit H21 with RSP
Attention! The connection may only be made when the power is off!
You can find the terminals for connecting the protective room traffic light pit in the case of
a shortened shaft pit on
ERG-2018, (wiring diagram sheet 5 of 8 / column 6-8).
The terminals are
GR-500-GG.
52
Connection of the Si-Kr. Folding support counterweight
S3N / S4N VSK
Attention! The safety circuit contacts may only be connected when the power is off!
The terminals for connecting the maintenance jack support contacts with a shortened
shaft head can be found on the circuit board X6 /, (circuit diagram sheet 4 of 8 / column 5-
6).
Terminals:
3M and 3N (normally open), as well as 4M and 4N (normally closed).
If not available, please bridge the terminals!
53
Connection of the normally open contact folding support
cabin VSG for the protective area traffic H22
Attention! The normally open contact may only be connected when the power is off!
The terminals for connecting the maintenance folding jack switch in the case of a short-
ened shaft pit can be found on
ERG-2018, (wiring diagram sheet 5 v.8 / column 6-8).
The terminals are
5M and 5N