KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 18 -
38
Mounting the LED shaft lighting
Technische Daten / Technical Datas:
Protection class: IP65
Light output: 960 - 1080 lumen / meter
Supply voltage: 230V AC with plug
Lifetime: 50,000 hours / Hours
Max. Strand length: 70 meters
The new LED shaft lighting provides good uniform illumination of
the elevator shaft, short installation time and high IP65 protection.
The set includes:
1.
1 piece
LED shaft lighting
with 10m cable & Schuko plug
2.
30 pieces
mounting dowels M6
3.
30 pieces
cable ties medium
4.
1 piece
clear bag with
Mounting instructions
1.
Install the shaft lighting in the shaft head in compliance with the legal and company-related
safety regulations.
The LED shaft lighting is fed from the shaft pit at the bottom!
2.
The shaft lighting type-3 is fixed in the shaft head over-
lapping, i.e. 2.5m on the ceiling. For this purpose, holes
should be drilled for wall plugs 6mm.
3.
Drive down with inspection while unwinding the tape di-
rectly. Please wear the personal protective equipment rec-
ommended for use.
At a distance of approx. 2.5m, a 6mm hole should be drilled
in the shaft wall for a mounting dowel. The shaft lighting type-
3 can be attached to this with a cable tie.
4.
The shaft lighting type-3 is fixed in the shaft pit overlap-
ping, i.e. 2.5m at the base or bottom. For this purpose,
holes for wall plugs 6mm should be drilled.
5.
For the electrical connection of the
shaft lighting according to the standards,
please use the shaft socket strip SDL-92,
which is mounted as shown in the picture
on the right.
After plugging in the mains plug of the
shaft lighting, the cable is tension-re-
lieved at the holder with the help of a ca-
ble tie!