Mounting CANopen ELGO-
LIMAX-SAFE-CP33
The measuring system can work at a shaft height of up to 100m
and a maximum speed of 4.0 m / s with a millimeter resolution. The
magnetic tape is fixed with shaft tab holders in the upper and lower
part of the shaft. Above the below shaft flag holder a shaft flag
holder is attached to the belt breaker.
It is important to pay attention to the correct spring preload.
Passed through a gap in the reader on the magnetic tape
Please also note the ELGO-LIMAX installation instruc-
tions!
Montage-Set
Assembly kit complete:
0. Reader with mounting bracket
1. 2x Shaft flag holder for top & bot-
tom
2. 1x Shaft flag holder for Tape
break switch
3. Bandolder below for Tape break
switch
4. Top band holder
5. Tension spring
6. 2x cable ties
7. 6x scres, u-washer, nuts &
Clamping claws
8. Tape breaker with cable and at-
tachment
9. Magnetic tape
Mount the shaft flag holder
1
in the shaft head in compli-
ance with the
legal and company-related safety regula-
tions
. With fastening set
4
(clamps) with a tightening torque
of 20 Nm.
2.
Attach the top end of the tape by inserting the holder
4
into
the shaft flag holder
1
. Before inserting the magnetic tape,
please check the orientation of the tape.
The printed arrows
on the magnetic tape must point to the shaft head
!
The image to the right shows you how to insert the tape into
the holder. Finally, the band end is secured with a cable tie
6
.
3.
Go down with inspection and unwind the tape directly.
Please wear the personal protective equipment recom-
mended for use. Avoid damage to the tape.
4.
Drive the cabin into the middle of the shaft and let the en-
tire belt into the shaft pit so that it hangs freely.