![KW DAVID-613 Manual Download Page 55](http://html1.mh-extra.com/html/kw/david-613/david-613_manual_2013611055.webp)
KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 55 -
106A
Commissioning
ELGO LIMAX SAFE CP33
Before starting the teach-in, you should read the specifications in the attachment pa-
rameters A4 and the shaft copying menu B43.
2.1
The CANopen shaft copying system
must
be in-
stalled properly. The activation then takes place in
the CANopen menu
A402
, in which a
YES
is en-
tered for encoder 1 activated.
2.2
In menu
A403
the
CAN bus
must be switched on.
This is done by activating in the menu item CAN bus:
a
YES.
2.3
A SAFE shaft copying system should be set in menu
B43 CANopen
encoder. The following selection is
made:
LIMAX-33CP SAFE
1.0 Teach-In Setup-1
Setup-1 config. means that the LIMAX33CP
has not yet done a basic configuration. The
basic configuration is only possible once
and is usually carried out before delivery!
3.1 Input – electromagnetic safety gear?
The option "yes" is only required if an electrical catch is to be controlled directly by
the electronic output eSGC on the LIMAX33CP.
Normally, this is not the case. Therefore:
No-
>
Continue with 3.2 Inspection
If you want to control an electromagnetic
safety gear or a TSB brake:
Yes ->
Continue with catch triggering
UP & DOWN, DOWN only and UP only
Yes ->
Continue monitoring the inspection
3.2 Input - Monitoring the Inspection ?
The LIMAX CP33 offers the options for inspection operation: monitoring / no ca-
bling. The monitoring mode monitors the inspection speed and the optional in-
spection limit switches.