KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 64 -
6. Insert the steel band through the
side opening on the reader. Check
the correct alignment of the holes
using the marks on the reader.
7. Push the sliding jaw through the
opening with the notch intended for
the steel strip.
8. Insert the aluminum strip from
top to bottom into the slot provided
for this purpose.
9. Please mount the reader
7
on
the holder
6
provided.
Up to 3
screws are available.
10. The holder with the reading
head is mounted on the cabin roof
with the
4 screws
provided.
11. Check the correct assembly.
The tape should be installed as ver-
tically and straight as possible.
12. Switch the car computer off with
the switch
S37
FKR at the inspec-
tion box.
13. The plug of the Kübler LES02
read head can be plugged into the
ASE unit when de-energized.
Subsequently, the switch
S37
can
be switched on again.