KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 23 -
59
Connection of the door unlocking contacts of the shaft
doors S9.2 to S9.n at RSH
With a shortened shaft head
Danger! The door unlocking contacts may only be connected when the power is off!
The terminals for connecting the door release contacts can be found on the X1-XP
(circuit diagram sheet 5 of 8 / column 6-8).
The terminals are 14 and 15.
60
Mounting the suspension cable
Install the suspension cable in the shaft in compliance with the legal and com-
pany safety regulations!
The ends of the suspension cable are marked with the control unit and the car!
The proven flat suspension cable
EHK40 / EHK48 is fixed in the
shaft with the enclosed suspen-
sion cable holders.
The set includes:
1.
3 flat
suspension cable
brackets, one of them with
Angle for the cabin
2.
1 piece
of mounting
material with mounting
instructions
The suspension cable must be
suspended tightly in the shaft
and components of the shaft /
cabin must not protrude into the
path of the suspension cable.
A minimum radius of 150mm
must be observed!