13.5
Response Time of the Frequency Error Evaluation
Response time with a sudden frequency drop:
Time calculations in the subsequent tables assume the following settings:
Sampling Time = 10 ms, Wait Time = 100 ms
-
Use Sampling Time for the calculation when f > 1/Sampling Time
-
Use reciprocal frequency 1/f when f < 1/Sampling Time
In addition to the delay times shown in the tables below, please add also the
hardware delay time of the corresponding output
(relay = 25 ms, analog output = 1 ms, digital output = 1 ms). The parameter Filter
is excluded.
*) Calculated values for response times assume that “Sampling Time” would be
greater than the reciprocal frequency 1/f.
Div. Filter = 10
With „Div. %-Value“ = 10:
11 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
210 ms*)
With „Div. %-Value“ = 20:
21 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
310 ms*)
With „Div. %-Value“ = 30:
31 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
410 ms*)
With „Div. %-Value“ = 40:
41 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
510 ms*)
Div. Filter = 5
With „Div. %-Value“ = 10:
5 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
150 ms*)
With „Div. %-Value“ = 20:
10 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
200 ms*)
With „Div. %-Value“ = 30:
15 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
250 ms*)
With „Div. %-Value“ = 40:
21 x (Sampling Time or (1/f)) + 1x Wait Time -> delay =
310 ms*)
Div. Filter = 3
With „Div. %-Value“ = 10:
1 x (Sampling Time or (1/f)) + 1x Wait Time -> delay 110
ms*)
With „Div. %-Value“ = 20:
2 x (Sampling Time or (1/f)) + 1x Wait Time -> delay 120
ms*)
With „Div. %-Value“ = 30:
3 x (Sampling Time or (1/f)) + 1x Wait Time -> delay 130
ms*)
With „Div. %-Value“ = 40:
5 x (Sampling Time or (1/f)) + 1x Wait Time -> delay 150
ms*)
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...