R60047.0002 - Index 2
EN – page 61 / 115
11.3
Runtime Test
These internal monitoring procedures run automatically and continuously in the
background:
Error code
SMCB
Error Message on PC
(Operator Software OS6.0) Instruction
H‘ 0000 0001
Sense Error 1
Incorrect voltage value at PWR sense
input X21 [4] or internal error
H‘ 0000 0002
Sense Error 2
Incorrect voltage value at PWR sense
input X22 [4] or internal error
H‘ 0000 0004
Encoder Supply Error
Short circuit resp. faulty circuit
for encoder supply or SMCB supply or
internal error
H‘ 0000 0008
Position Error
Position error detected
Parameter “Div. Mode” = 1, 2
H‘ 0000 0010
Encoder Line Error 1
Error in encoder tracks at X21 or internal
error
H‘ 0000 0020
Encoder Line Error 2
Error in encoder tracks at X22 or internal
error
H‘ 0000 0040
EDM Error
Error when controlling or rereading the
external relay or internal error
H‘ 0000 0080
Sensor Overlap Error
Error in sensor cover
H‘ 0000 0100
Temperature Error
Impermissible high temperature
H‘ 0000 0200
Digital Output Error
Short circuit resp. faulty circuit at the control
outputs or internal error
H‘ 0000 0400
Analog Error
Open analog output (
H‘ 0000 0800
Relais Output Error
Relay control error, contact readback error
H‘ 0000 1000
Direction Error
Too many change of direction, possibly a
encoder track torn off
H‘ 0000 2000
Digital Input Error
Illegal transition state at the inputs
H‘ 0000 4000
Signal Error 1
n.a.
H‘ 0000 8000
Signal Error 2
n.a.
H‘ 0001 0000
Phase Error 1
Illegal signal change at Encoder 1
H‘ 0002 0000
Phase Error 2
Illegal signal change at Encoder 2
H‘ 0004 0000
Frequency Error
Frequency error F1
≠
F2
Parameter Div. Mode = 0, 2
H‘ 0008 0000
Drift Error 1
Drift error at Encoder 1
H‘ 0010 0000
Drift Error 2
Drift error at Encoder 2
H‘ 0020 0000
Internal Error (ESM)
Internal error
H‘ 0040 0000
Undervoltage Error
Under Voltage detected
H‘ 0080 0000
Wrong Parameter Error
Simulation
Parameter "Error simulation"
≠
1 for DIL-
switch setting "Normal operation"
H‘ 0100 0000
Internal Error (REG)
Internal Error
H‘ 0200 0000
Internal Error (CYC)
Internal Error
H‘ 0400 0000
Internal Error (CLK)
Internal error
H‘ 0800 0000
Wrong Parameter Setting
Frequency too high for parameter setting
"Sampling Time" (overflow) or ramp time
set too high
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...