STO/SBC/SS1 by Input
(Switch Mode = 10)
With parameter setting “Switch Mode” = 10, an STO, SBC or SS1 function is assigned to
the output. The function requires an enable input signal which is assigned by the „Matrix
“ parameter. Parameter “Lock Output” can be used to activate a lock function,
which can be acknowledged by a further input. Acknowledgement is only possible with
deactivated enable signal. There is no frequency or ramp monitoring.
Relevant Parameters
Remark
„Switch Mode
“
= 10
„Matrix
“
use only inputs, but no feedback outputs
„MIA-Delay
“
= 0
„MAI-Delay
“
= 0
„Lock Output“
for lock function use only range 0-31
„Output Mode“
homogenous or inverse output configuration (affects the Safety Integrity
Level SIL/PL)
„Delay
“
„Input Mode “
configuration of the control inputs (affects the safety level SIL/PL)
„ IN Function“
function of the control input
„ IN Config“
switching behaviour (single-channel, two-channel, inverse, homogeneous,
dynamic, static)
Relevant input functions
Remark
Enable, e.g. Parameter „IN1 Function“ = 21
activates the function
Clear lock function, e.g. parameter „IN2 Function“ = 1 … 6 Only when lock function is active
Important:
A safety function will not be achieved before the SMC2.4 monitor has been
combined with a corresponding actuator unit.
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...