R60047.0002 - Index 2
EN – page 88 / 115
Continuation
„ramp monitoring (Switch Mode = 22)“:
Relevant Input function
Remark
Enable, e.g. Parameter „IN1 Function“ = 21
activates the function
Clear lock function, e.g. parameter „IN2 Function“ = 1 … 6
Only when lock function is active
The window is determined by the "Presel.
.
" and is entered directly in 0.00 Hz
values. An input of 100.00 Hz generates a range of + 100.00 Hz by the calculated
frequency. The parameter "Presel.
.F" indicates the braking ramp.
If lock function has been activated, the Delay parameter must also be activated. It must
be set at least to the smallest value of 2ms.
Example:
If a braking ramp is triggered from 0.01 Hz/ms at 1353 Hz, the time to 0 Hz is reached:
1353 Hz/(0.01 Hz/ms) = 135.3 s = 2min 15,3s
To determine the ramp, the drive should be braked at e.g. 1kHz and the time duration
measured. The parameter value follows by calculation.