R60047.0002 - Index 2
EN – page 20 / 115
5.4.2
Control outputs CONTROL IN 2
The following functions and configuration options are available on the terminal strip
[X24 | CONTROL IN 2]:
•
Two 2-pole inputs (IN3, /IN3 und IN4, /IN4)
Signalpair 1
[X24: 2] IN3
Control signal 5, fault detection
[X24: 3] /IN3 Homogeneous or inverse control signal 5, fault
detection
Signalpair 2
[X24: 4] IN4
Control signal 6, fault detection
[X24: 5] /IN4 Homogeneous or inverse control signal 6
•
One 2-pole input (IN3, /IN3) and ztwo 1-pole inputs (IN4 and /IN4)
Signalpair 1
[X24: 2] IN3
Control signal 5, fault detection
[X24: 3] /IN3 Homogeneous or inverse control signal 5
Signal 2
[X24: 4] IN4
Control signal 6
Signal 3
[X24: 5] /IN4 Control signal 7
•
Four 1-pole inputs (IN3, /IN3, IN4 and /IN4)
Signal 1
[X24: 2] IN3
Control signal 5
Signal 2
[X24: 3] /IN3 Control signal 6
Signal 3
[X24: 4] IN4
Control signal 7
Signal 4
[X24: 5] /IN4 Control signal 8
•
One 4-pole input (IN3, /IN3, IN4 and /IN4)
Signal 1 - 4
[X24: 2-5]
Signals in gray (4 states with error detection) or
binary format (16 states without error detection)
for switching the switching points
•
The use of 1-pole inputs reduces the Safety Integrity Level (SIL) or
the Performance Level (PL).
•
The use of 16 switching points reduces the Safety Integrity Level
(SIL) or the Performance Level (PL).
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...