R60047.0002 - Index 2
EN – page 31 / 115
6.3
Combination: RS422 + HTL (A, B, 90°)
Device:
SMC2.4
„Op-Mode 1“:
0
Sensor 1:
[X21 | ENCODER IN 1]:
RS422 Encoder
A, /A, B, /B, (Z,/Z)
„Op-Mode 2“:
2
Sensor 2:
[X22 | ENCODER IN 2]:
HTL (A,B,90°)
Encoder
A, B, (Z)
Safety Level:
Speed
SIL3 / PLe achievable (see below)
Direction
SIL3 / PLe achievable (see below)
Standstill
SIL3 / PLe achievable (see below)
The combination HTL (A; B; 90°) + RS422 is also possible, the sensors, the encoder
supplies and the settings have to be adjusted accordingly.
The encoder supply of the encoder 1 can also be done over 5 V
•
The final Safety Integrity Level (SIL) and Performance Level (PL)
depends on the selected configuration and on external components
connected to the unit.
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...