R60047.0002 - Index 2
EN – page 39 / 115
7
Operation modes SMC1.3
The following operating modes are suitable for mapping a system with a SIL2/PLd
certified sensor. The encoder tracks in the SMC1.3 are internal bridged (two-channel
structure).
The following operation modes are possible:
Sensor 1 – SIL2 / PLd
z certified –
Sensor 2 –
internal bridged
–
Format
Required
signals
Optional
signals
Format
Required
signals
Optional
signals
RS422
A, /A, B, /B
Z, /Z
RS422
internal
bridged
internal
bridged
HTL
differential
A, /A, B, /B
Z, /Z
HTL
differential
internal
bridged
internal
bridged
The Z or/Z track is not evaluated by the device.
Only the line breakage monitoring of the Z tracks is active.
•
The final Safety Integrity Level (SIL) and Performance Level (PL)
depends on the selected configuration and on external components
connected to the unit.
•
At the SMC1.3, SIL2 / PLd can be reached.