R60047.0002 - Index 2
EN – page 41 / 115
7.2
Combination: HTL (differential) SIL2 / PLd Encoder
Device:
SMC1.3
„Op-Mode 1“:
1
Sensor 1:
[X21 | ENCODER IN 1]:
SIL2 / PLd HTL
Encoder
A, /A, B, /B, (Z,/Z)
„Op-Mode 2“:
1
Sensor 2:
[X22 | ENCODER IN 2]:
unbenutzt
(intern gebrückt)
Safety Level:
Speed
SIL2 / PLd achievable (see below)
Direction
SIL2 / PLd achievable (see below)
Standstill
SIL2 / PLd achievable (see below)
•
The final Safety Integrity Level (SIL) and Performance Level (PL)
depends on the selected configuration and on external components
connected to the unit.
•
At the SMC1.3, SIL2 / PLd can be reached.
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...