55
4.5 RECORD
Please click (
) RECORD and the following screen will appear.
4.5.1 Setting
Please click (
) RECORD>Settings and the following screen will appear.
There are three kinds of recording mode.
-
Continuous:
record continuously.
-
Event:
record only when Sensor or Motion calls.
-
Emergency:
record when press
EMERGENCY
key.
NOTE
A, B, C and D Type
does not have HD-SDI Input tap.
The Continuous menu will allow user to set recording mode.
Each frame on Title column shows camera title registered in DEVICES>Camera/PTZ. User cannot change camera titles
here.
Click (
) each frame on Resolution column to select recording resolution of a corresponding camera. User may select one
of
360x240(288), 720x240(288), 720x480(576), 960x480(576), 1280x720 and 1920x1080.
Click (
) each frame on Frames column to select recording rate of a corresponding camera. Recording rate varies by
camera. Below lists the maximum recording rate of each camera.
A, B, C and D Type
NTSC(PAL)
360x240 (360x288)
720x240 (720x288)
720x480 (720x576)
960x480 (960x576)
4 Channel DVR
120 (100)
120 (100)
120 (100)
120 (100)
8 Channel DVR
240 (200)
240 (200)
240 (200)
240 (200)
16 Channel DVR
480 (400)
480 (400)
480 (400)
480 (400)
Continuous
Summary of Contents for KM2115DKQCN
Page 12: ...12 B Type 4 8 16 channel Series DVR...
Page 13: ...13 C Type 4 8 16 channel Series DVR...
Page 14: ...14 D Type 4 8 16 channel Series DVR...
Page 15: ...15 E 4CH Type 4 channel Series HD SDI DVR...
Page 16: ...16 E 8 16CH Type 8 16 channel Series HD SDI DVR...
Page 17: ...17 F Type 4 8 16 channel Series HD SDI DVR...
Page 18: ...18 G Type 4 channel Series HD SDI DVR...
Page 19: ...19 H Type 4 channel Series HD SDI DVR...