Terminal – menus [Medium 1.0/Comfort 1.0]
13
Menu 4 "Bale scales" 13.10
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
157
Setting the bale scales
ü
The machine is shut down and safeguarded,
.
ü
The bale chute has been lowered
.
Check
Place a calibrated test weight from 200 - 300 kg in the centre of the bale scales.
Read off the displayed weight.
Æ
If the displayed value corresponds to the weight of the test weight, it is not necessary to
adjust the bale scales.
Æ
If the displayed value differs from the weight of the test weight, the bale scales must be
adjusted.
Adjusting bale scales
Press
or
until the value (2) corresponds to the weight of the test weight.
To save the value, press
.
Æ
The
icon is briefly displayed and the value is saved.
INFORMATION
If the limit range is not adequate to adjust the bale scales, contact KRONE customer
service.
Zeroising bale scales
If there is no bale (weight) on the bale scales, but a value (2) is displayed, when the bale chute
is lowered, the sensors B55 "Bale chute at rear" and B56 "Bale chute at front" must be zeroised.
During the zeroising process the acceleration sensor is calibrated.
ü
The bale chute has been lowered
.
ü
There is no bale (weight) on the bale scales.
ü
The machine is shut down and safeguarded,
.
To zeroise the bale scales, press
.
ð
The
icon is briefly displayed and the acceleration sensor is calibrated.