Malfunction, cause and remedy
22.1
Malfunction in the electrics/electronics
308
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
522317-
K30
Actuator K30 “Cleaning 1“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522318-
K33
Actuator K33 “Cleaning 2“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522319-
K05
Actuator K05 “Bale ejector plunger surface“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522320-
K06
Actuator K06 “Bale ejector annular surface“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522321-
FMA1
Force measurement amplifier 1 (FMA 1) “Baling force control”
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
FMI 1: The lower limit value was far below the required one.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.