Machine description
4
Hydraulic system
4.9
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
53
lubrication system with a pressure limiting valve. If a lubrication point does not take any grease
from the distributor, the progressive distributor blocks and a pressure of 280 bar (4060 PSI)
builds up in the central lubrication system. Grease emerging on the pressure limiting valve of
the pump element indicates a blockage. Error messages appear in the display of the terminal.
Design of the central lubrication system
An electrically driven piston pump delivers lubricant to the main progressive distributor. Its task
is to distribute grease to the sub-progressive distributors at the correct ratio. Then, the sub-
progressive distributors pump the grease to the individual lubrication points. The lubrication
duration and the break times are controlled via terminal,
BP000-282
1
Reservoir
5
Lubrication points
2
Pressure limiting valve
6
Lubricant line
3
Main distributor
7
Main line
4
Auxiliary distributor
8
Filling nipple
>>>
2
Setting the target bale channel flap pressure (manual mode) [
4.9
Hydraulic system
For “Comfort 1.0” version
1
BPG000-018
The hydraulic system of the machine has been designed in the factory for continuous
circulation. The system screw (1) is fully unscrewed.
The hydraulic system of the machine is Load Sensing capable. When using the Load Sensing
system, the oil is supplied via Power Beyond system of the tractor hydraulics.
Please refer to the operating instructions of the tractor manufacturer for further information.