Malfunction, cause and remedy
22
Malfunction in the electrics/electronics
22.1
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
277
Before contacting the dealer, collect the following information about the error message:
Note the error number and the respective FMI (
display.
Shut down and safeguard the machine,
.
Check sensor/actuator externally for damage.
Æ
If the sensor/actuator is damaged, replace the sensor/actuator.
Æ
If the sensor/actuator is not damaged, continue with the next test step.
Check connector cable and plug connection for damage and tightness.
Æ
If the connector cable/plug connection is damaged, replace the connector cable/plug
connection.
Æ
If the sensor/actuator is not damaged, continue with the next test step.
Perform an actuator test in case of an actuator error to identify the actuator status,
.
If a sensor is defective, run a sensor test to identify the sensor status,
The more information the dealer has, the easier it is to eliminate the cause of the error.
22.1.4
Error list of all error messages
520192-
KBT
KRONE operating terminal (KOT)
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring,
The operating terminal is de-
fective.
Note the error number and the FMI. Then contact the
dealer.
520193-
KBT
KRONE operating terminal (KOT)
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring,
The operating terminal is de-
fective.
Note the error number and the FMI. Then contact the
dealer.
520194-
KBT
KRONE operating terminal (KOT)
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring,
The operating terminal is de-
fective.
Note the error number and the FMI. Then contact the
dealer.
520195-
KBT
KRONE operating terminal (KOT)