Electric connection - outdoor module
■
You can apply a low tariff and a blockade of electricity supply by the energetic plant.
■
When using the low tariff with blockage of electricity supply by the energetic plant,
no parameter settings are required. Compressor during blockade is turned off.
■
During the blockade of electricity supply by the energy company, they are not
supported diagnostics functions of the outdoor module.
Free clamps for internal use only
/1
/ 1
B
A
A
- Connection space for the external module
B
- Electrical connection 230 V/50 Hz
Types
Cord
Max. cord's
length
Max.
safety
HPSO-6/230
3 x 2,5 mm
2
lub
3 x 4,0 mm
2
31m
lub
32m
B25A
HPSO-8/230
20m
lub
32m
B25A
Electrical connection to 230 V ~ outdoor module
Electrical connection to 400 V~ outdoor module
/ 1
B
/ 1
A
//
/
/
The wrong phase sequence can cause damage device. Only carry
out the electrical connection in accordance with the given phase
sequence (see connection clamps), with a clockwise rotating field.
A
- Connection space for the external module
B
- Electrical connection 400 V/50 Hz
Types
Cord
Max. cord's
length
Max.
safety
HPSO-12/400
HPSO-16/400 5 x 2,5 mm
2
60m
3 x B13A