Electrical values of the indoor unit
HPSO-12/400
+HPSI-09
HPSO-16/400
+HPSI-09
Air inlet temperature
Heating mode
Min
°C
–22
Max.
35
Cooling mode
Min.
°C
10
Max.
48
Heating water
Minimum flow rate
l/h
900
Minimum capacity of the heating
system, without cut off
l
52
70
Max. external pressure drop (RFH)
at min. flow rate
mbar
kPa
700
70
Max. flow temperature
°C
55
Electrical values of the external unit
Rated voltage, compressor
3/N/PE 400 V/50 Hz
Max. rated current, compressor
A
10,6
Cos φ
1,00
Starting current, compressor
A
5
Fuse protection
3 x B13A
IP rating
IPX4
Heat pump control unit/PCB
Rated voltage
1/N/PE 230 V/50 Hz
Internal fuse
T 6,3 A/250 V
Fuse protection, power supply
1 x B16A
Instantaneous heating water heater
Rated voltage
1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
Heating output
kW
9,0
Fuse protection, power supply
B40A / 3 x B16A